Cementitious Floor Toppings for Commercial Floors: When They Fit
Cementitious Floor Toppings for Commercial Floors in Denver
Colorado Concrete Repair quotes floor toppings for uneven or damaged commercial floors in Denver. Our quotes use a self-leveling floor leveler, a polishable overlay at least 1/2 inch thick or a 1/4 inch urethane cement topping. We work on commercial and industrial floors. We don’t do driveways, patios, pool decks or houses. Pole barns are the one exception. Want a resin coating instead? See our epoxy flooring services.

Since 2009
Commercial and industrial floor repair and surface work from our Denver base.
Toppings We Quote
Self-leveling floor leveler, polishable overlay and 1/4 inch urethane cement.
Cure by Product
Cure time depends on the product and site conditions. The maker’s data sheet sets it.
When a Commercial Floor Needs a Cementitious Topping
Open a topic to see when a topping fits, what our quotes list and how the work gets planned.
When should a commercial facility use a cementitious floor topping?Fit and limits▼
Short answer: Use one when the floor is uneven or damaged on top and the concrete below can stay. Skip it when the floor has to come out or needs engineering. We do partial-depth repair and surface work, not slab replacement. Our quotes use a leveler, a polishable overlay or a 1/4 inch urethane cement topping.
✓ Fits when:
- The floor is out of flat. One of our quotes lifts it with Uzin NC 157, no more than 2 inches, to a working floor flatness grade.
- A floor height change tops 1/4 inch. FacilitiesNet lists that as a hazard.
- You want a polished finish. One of our quotes levels the floor, places at least 1/2 inch of Rapid Set TRU PC and polishes it.
- The room is a brewery or a food, beverage or pharmaceutical plant. Resinwerks lists BIO-CEM MF urethane cement for those uses.
Limits:
- Floors that need replacement or engineering are outside our work.
- An old underlayment leveler that isn’t suitable for the final floor may have to come out first.
- Our standard terms price a floor under 75 percent relative humidity or 3 lbs per 1,000 sq ft. Above that, a moisture mitigation system may be added by change order.
Want a resin coating instead? See our commercial flooring options page.
What Our Topping Quotes ListPrep and steps▼
In our quotes: Our urethane cement and overlay quotes call for grinding or media blasting to a CSP of 2 or greater, with the equipment attached to HEPA vacuums. The rest of the steps depend on the floor and the product.
✓ Urethane cement quotes list steps such as:
- Grind or media blast to a CSP of 2 or greater on HEPA vacuums
- Patch cracks and spalls with thickened Vapor Barrier Epoxy where the floor needs it
- Install 1/4 inch BioCem MF seeded with 40-grit silica sand to rejection
- Sweep and vacuum, then in one Denver quote a Kinetic HS polyaspartic coat and an HDC-100 urethane topcoat
Overlay and leveler quotes list steps such as:
- Remove an old underlayment leveler that isn’t suitable for the final floor
- Prime and install Rapid Set Concrete Leveler
- Place at least 1/2 inch of Rapid Set TRU PC, then grind, grout, hone, densify and polish it
Steps change with the floor and the product. See our installation process.
How the Work Gets PlannedProcess & scheduling▼
Planning: Access, phasing and off-hours work can be part of the quoted plan. Cure time depends on the product and site conditions.
✓ What a plan can include:
- Phased work, one zone at a time
- Off-hours work, when it’s quoted
- HEPA vacuums on the grinders and blasters
- Resinwerks lists an install window of 40 to 85 F for its urethane cement
Limits:
- Cure time depends on the product and site conditions
- A moisture mitigation system above our terms’ limits may be added by change order
- Foot traffic, vehicles and chemicals return when the maker’s data sheet says
Give us a call or request a site assessment.

FLOOR TOPPING QUESTIONS
Frequently Asked Questions
Do you install micro toppings or topping slabs?
None of the 168 quotes we reviewed include a micro topping or a newly poured topping slab. Micro topping searches mostly lead to product and do-it-yourself pages. Over an existing commercial floor, our quotes use a self-leveling floor leveler, a polishable overlay at least 1/2 inch thick or a 1/4 inch urethane cement topping.
How thick is a concrete topping?
It depends on the product. Resinwerks lists BIO-CEM MF urethane cement at 3/16 to 1/4 inch and BIO-CEM SL at 1/8 inch. Sherwin-Williams lists Poly-Crete HF at 1/4 to 3/8 inch. Our overlay quotes call for at least 1/2 inch of Rapid Set TRU PC. One leveler quote allows a lift of Uzin NC 157 up to 2 inches.
Can you put a topping over existing concrete?
Yes, when the concrete below can stay. Our urethane cement and overlay quotes grind or media blast to a CSP of 2 or greater on HEPA vacuums. Cracks and spalls get patched where the floor needs it. An old leveler that isn’t suitable for the final floor may have to come out first.
Can this work be done while our facility stays operational?
It can be planned around your operation. Access, phasing and off-hours work can be part of the quoted plan. Cure time depends on the product and site conditions. The maker’s data sheet sets when foot traffic, vehicles and chemicals can return.
How do I choose a contractor for a floor topping?
Ask to see the steps in writing. Our urethane cement and overlay quotes name the product, the thickness and prep to a CSP of 2 or greater. Ask which makers they install. We install Resinwerks, Dur-A-Flex, Metzger/McGuire and Sherwin-Williams resin flooring regularly. Also ask whether the floor needs a topping at all.
Request a Site Assessment
Give us a call and we’ll set up a time to look at your floor. We quote floor repair, levelers, overlays and urethane cement.